0
home

Fire Retardant Plywood IS:5509

home
Fire Retardant Plywood IS:5509
Fire Retardant Plywood IS:5509
Price And Quantity
  • Piece/Pieces
  • 7000
  • Piece/Pieces,
  • 1INR
  • 98.00-
Product Specifications
  • Furniture
  • Customized as per Oreder
  • other
  • 12 to 75 Millimeter (mm)
    Product Description

    STONIC is a excellent Fire Retardant Plywood IS:5509 with extremely good resistance capacity from fire. This special grade is treated with proven fire retardant chemicals at the time of manufacture and completely composed with high density hard wood veneers. With boiling water proof marine grade quality standards, STONIC FRP is uniquely processed for creating a super resistance from fire.

    STONIC FRP is manufactured as per IS:5509 specifications that ensures the flammability test, rate of burning and flames to penetrate in plywood as per the Bureau of Indian Standards.

    STONIC FRP is advisable to be used in public places, where the risk of fire has to be reduced. The areas such as in kitchen woodwork of large restaurants, interior woodwork public auditoriums, theatres and banquet halls. STONIC FRP is very suitable for every application in premium homes and villas as it confirms to all requisites of IS 710 and IS 5509. It can be used in railway compartments of railway trains or other public transport or station facilities. STONIC FRP is the most suitable plywood panel for high rise commercial buildings as this will prevent the occupants from fire and fumes for an extended period of time to provide enough escape time.

    STONIC FRP is the best product for any interior wood working, specially at such places where the risk and spread of fire has to be reduced.

    STONIC FRP resists Spark and Ignite without any penetration. It offers 30 % lesser smoke generation with extended flame penetration time. It offers very Slow burning, having a decreased tendency of the fire to spread over the surface of the plywood.

    USES : Ships, Bus coaches, Cinema Halls, High rise buildings, Restaurants, Railway Coaches, Vehicle Bodies in Boiler House, Kitchen, Inner Roof Wall Linings, Exhibition Stalls, Public places, Offices, Homes etc

     

    Available Dimensions :

     

    Standard thickness : 6mm, 9mm, 12mm, 16mm, 19mm, 25mm

    Standard Size : 2440 x 1220 mm.

    Customize sizes are also available as per customers requirement.

    Properties :

    S.
    NO.

    TEST DESCRIPTION

    SPECIFIED REQUIREMENT

    OBSERVATION

    Dimensional Requirement

    1.

    Length
    Width
    Thickness
    Squareness
    Edge Straightness

    ( + ) 6 mm., ( - ) 0 mm.
    ( + ) 3 mm., ( - ) 0 mm.
    < 6 mm + 10 %, 6 mm + 5 %
    0.2 %
    0.2 %

    With in tolerance limits

    Physical Parameters

    2.

    Glue shear Strength (In Dry State)
    Average
    Minimum Individual
    Adhesion of plies (knife test)


    1350
    1100
    Shall be min. pass standard


    1630
    1540
    Excellent

    3.

    Water Resistance Test
    Average
    Minimum Individual
    Adhesion of plies (knife test)


    1000
    800
    Shall be min. pass standard


    1440
    1250
    Excellent

    4.

    Tensile Strength (In N/mm2)
    Parallel to the face grains
    Perpendicular to the face grains
    Sum of Tensile Strength (1+2)


    42
    25
    84.5


    54
    44
    98

    5.

    Static Bending Strength
    Across (Direction perpendicular to the grain direction of face veneer)
    Modulus of Elasticity (MOE) in N/mm2
    Average
    Minimum Individual
    Modulus of Rupture (MOR) in N/mm2
    Average
    Minimum Individual





    4000
    3600

    30
    27





    4870
    4350

    34
    32

    Fire Retardant Requirement as per IS 5509:2000

    6.

    Flammability

    Time taken for the second ignition shall not less than 30 min.

    65 min.

    7.

    Flame penetration

    15/6 x thickness min.

    55 min for 12 mm thickness

    8.

    Rate of Burning

    Not less than 20 min.

    40 min minimum

    Burning Rate Test as per IS 15061:2002

    9.

    Horizontal Burning Rate, mm/minute (Along the grain direction of the face veneer) as per IS 15061:2002, Annexure A, Clause 3.2

    The result of the test shall be satisfactory if, taking the worst test results into account, the horizontal burning rate is not more than 100 mm/minute or if the flame extinguishes before reaching the last measuring point.

    The flame extinguishes before reaching the last measuring point.

    The material meets horizontal (Along) flammability requirements.

    10.

    Horizontal Burning Rate, mm/minute (Across the grain direction of the face veneer) as per IS 15061:2002, Annexure A, Clause 3.2

    The result of the test shall be satisfactory if, taking the worst test results into account, the horizontal burning rate is not more than 100 mm/minute or if the flame extinguishes before reaching the last measuring point.

    The flame extinguishes before reaching the last measuring point.

    The material meets horizontal (Across) flammability requirements.

    Trade Information
    • Cheque, Cash in Advance (CID)
    • 1000 Per Month
    • 10-15 Days
    • All India
      Related Products
      Compreg Plywood




      Send Inquiry
      Marine Grade plywood




      Send Inquiry
      MR Grade Container Flooring Plywood




      Send Inquiry
      Marine Grade plywood IS:15061




      Send Inquiry
      Film Faced Shuttering Plywood




      Send Inquiry
      Shuttering Plywood




      Send Inquiry
      right arrow
      left arrow
      Contact Us

      B No 126 , Badi Majra  Yamunanagar  Haryana  India  +918037304218
      Phone :+918037304218